Roof Anchor Testing

Roof Top Anchor & Davit Arm Load Testing

Liftsafe Engineering and Service Group Inc. offers a range of services related to non-destructive load testing of roof top fall arrest anchors and davit arm assemblies.

  • Inspections shall be complete according to CSA Z91 (7.3.2.1) at intervals not exceeding twelve (12) months.
  • All new anchors shall be inspected and tested according to CSA Z91 (7.3.1) and CSA Z271 (6.3.2b). A Professional Engineer or a qualified person under the supervision of a Professional Engineer shall complete the inspection and load testing of new anchors.
  • All adhesive or expansion anchors shall be tested at intervals not exceeding five (5) years, in accordance with clause 6.3.2b of CSA Z271.
  • Inspections of structural components shall include, but not be limited to:
  • A review of the design drawings to ensure compliance with current regulations standards and engineering standards.
  • An inspection of the system to ensure compliance with the engineered drawings.
  • An inspection of all exposed, visible and accessible components of the system for signs of stress.